Products
RL-16 Series Metal Tube Thermal Fuse
Classification:
Keyword:
Download:
This thermal fuse is a single‑use safety protection component rated at 16 A and 250 V, with an operating temperature range from 77 °C to 240 °C. Household appliances, motors, transformers, heating equipment, and other related fields.
Online MessagePrevious:
Dimensions (unit: mm)
| A | C | D | E | F |
| 35.0±1.0 | 20.0±1.0 | Φ1.0±0.1 | Φ4.0±0.1 | Φ1.0±0.1 |
Product Features and Applications
|
Materials |
Leadwire: Tin-Plated Copper Wire/Silver-Plated Copper Wire Sealing Resin: Epoxy Resin Ceramic bushing: Ceramic Metal case: Silver Plated Copper |
||||||
|
Features |
No-resettable | ||||||
| High accuracy of function temp | |||||||
| Environmentally friendly, RoHS & REACH compliant | |||||||
|
Application |
Lighting fixtures, switch-mode power supplies, household appliances, electric motors, transformers, electronic components, telecommunications, and other fields. Lamps, Switching Power Supplies, Home Electrical Appliances, Motors, Transformers, Components, Communications Field, etc. |
||||||
EXPLANATION OF TERMS
|
Rated operating temperature (TF) |
Temperature of the thermal link which causes it to change its state of conductivity with a detection current up to 10 mA as the only load. The thermal fuse must blow within the range of +0/–10°C. |
|||||||
|
Fusing-off temperature |
The fusing-off temperature is the value measured in the test oil bath, with the temperature increased steadily. with a rate of rise between 0.5 K/min and the detection current of 10 mA or less. |
|||||||
|
Maintain temperature (Th) |
The maximum temperature at which a thermal-link will not cause a change in state of conductivity to open circuit. while conducting rated current for 168 hours or according to IEC60691. |
|||||||
|
Maximum Limit Temperature (Tm) |
Temperature of the thermal-link stated by the manufacturer, up to which the mechanical and electrical properties Once the thermal link changes its state of conductivity, it will remain unaffected for a specified period. |
|||||||
|
Model |
Rated operating temperature |
Measured operating temperature |
Maintain temperature |
Maximum Limit Temperature |
Rated current |
Rated voltage |
Safety Approvals | |
|
|
![]() |
|||||||
| Tf(℃) | ℃ | Th(℃) | Tm(℃) | Ir(A) | Ur(V) | |||
| RL77-16 | 77 | 74±3 | 47 | 300 | 16A | 250V | ● | ● |
| RL94-16 | 94 | 91±3 | 64 | 300 | 16A | 250V | ● | ● |
| RL99-16 | 99 | 96±3 | 69 | 300 | 16A | 250V | ● | ● |
| RL104-16 | 104 | 101±3 | 74 | 180 | 16A | 250V | ● | ● |
| RL110-16 | 110 | 107±3 | 80 | 300 | 16A | 250V | ● | ● |
| RL113-16 | 113 | 110±3 | 83 | 300 | 16A | 250V | ● | ● |
| RL121-16 | 121 | 118±3 | 91 | 300 | 16A | 250V | ● | ● |
| RL133-16 | 133 | 130±3 | 103 | 300 | 16A | 250V | ● | ● |
| RL142-16 | 142 | 139±3 | 112 | 190 | 16A | 250V | ● | ● |
| RL157-16 | 157 | 154±3 | 130 | 200 | 16A | 250V | ● | ● |
| RL167-16 | 167 | 164±3 | 137 | 300 | 16A | 250V | ● | ● |
| RL172-16 | 172 | 169±3 | 145 | 210 | 16A | 250V | ● | ● |
| RL184-16 | 184 | 181±3 | 160 | 240 | 16A | 250V | ● | ● |
| RL192-16 | 192 | 189±3 | 170 | 240 | 16A | 250V | ● | ● |
| RL216-16 | 216 | 213±3 | 190 | 380 | 16A | 250V | ● | ● |
| RL229-16 | 229 | 226±3 | 200 | 380 | 16A | 250V | ● | ● |
| RL240-16 | 240 | 237±3 | 200 | 380 | 16A | 250V | ● | ● |
Factory Real Scene
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
Certification
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
This is placeholder text.
WHY CHOOSE US?
We are not just selling fuses, but providing you with a "foolproof" circuit protection solution.
Authentic materials, rejecting the 'time bomb'
Fully certified and globally accessible
Lean production, safe and reliable
The product can be customized
FAQ
What certifications do you have?
Certification Standards: UL, CUL, VDE, CCC, PSE, KC (different models are subject to different certifications; please consult customer service for confirmation).
Product Center

